1,rview of Endoscopy

An endoscope is a testing instrument that integrates optics, ergonomics, precision machinery, modern electronics, and software. Including image sensors, optical lenses, lighting systems, mechanical devices, etc. It is a very convenient tool to insert the camera into the object that needs to be detected through a hose or hard tube, and connect the monitor at the other end to clearly observe the internal image.

2,lassification of endoscopes

 

(1)According to different digital signal processing methods, cameras can be divided into two categories: digital endoscopes and analog endoscopes.

Analog endoscopic cameras can convert analog video signals generated by video capture equipment into digital signals and store them in the computer. The video signal captured by the analog camera must be converted into a digital mode through a specific video capture card and compressed before it can be converted to a computer for use. The overall cost of analog cameras is relatively high and they are no longer a mainstream product.

The digital endoscope camera can capture images directly and then transfer them to a computer via a USB interface or overlay them on a display screen with a smartphone. The cameras on the market now are mainly digital cameras, and the digital cameras are mainly USB digital cameras that use new data transmission interfaces. Most of the cameras currently on the market are such products.

 

(2) In terms of application, it can be divided into two categories, namely industrial endoscopes and medical endoscopes.

Industrial applications mainly refer to non-destructive testing and borehole exploration technology. Product application industries include: construction engineering, oil and gas chemical industry, mechanical maintenance, safety inspection, automobile maintenance, electrical facility testing, pipeline chemical industry, aerospace, etc.

 

In the medical field, it is mainly used in various types of medical examinations and medical operations, by inserting the endoscopic camera tube into the body to find problems and deal with related problems. Main applications include gastroenteroscopy, bronchoscopy, colonoscopy, hysteroscopy, etc.

 

3,Working principle of endoscope

info-1200-800

 

The endoscope transmits the internal image of the device to the outside of the device through the camera, and allows the inspector to view the internal image in real time through the monitor. After the lighting system provides an internal light source, the light passes through the lens of the camera to form an optical image inside the camera. This optical image is then projected onto the image sensor. The image sensor receives the reflected light from the object being inspected, converts the light into an electrical signal, and uses the digital signal processing chip to process the digital image signal of the image sensor through a series of complex mathematical algorithms. Optimize processing of digital image signals. Finally, the computer receives these processed digital image signals through the USB interface and displays them on the screen so that the user can watch and use them.

4. Structure and components of endoscope

(1)Lens: The lens of the endoscope camera is a lens structure composed of several lenses, which can be divided into plastic lenses and glass lenses. The main function of the lens is to focus the light from the scene on the camera's image sensor.

  (2) Image sensor (SENSOR): The image sensor of the camera can be divided into two types: CCD and CMOS. CCD sensors respond quickly to light and are suitable for high-speed shooting; while CMOS sensors are more power-saving and suitable for low-power applications.

(3)Digital signal processing chip (DSP): The digital signal processing chip (DSP) is one of the core components of the camera. The main function of DSP is to process and compress image signals in order to transmit and store image data more effectively.

(4)Power supply: There are two commonly used voltages for endoscopes: 3.3V and 5V. Different power supplies have different connecting wires. Special attention is required when using them to avoid short circuits caused by overload.

 

5,Main technical indicators of the camera

 

(1) Resolution:

Resolution refers to the size of the image that the camera can capture, usually expressed in pixels. Common resolutions include:

pixel value

resolution

pixel value

resolution

5MP

2592 x 1944

2MP

1920 x 1080, also known as 1080

1MP

960 x720,also known as 720P

VGA

640 x 480, also known as 0.3MP

 

(2)Image output format

Images captured by endoscopic cameras can be in a variety of formats, with MJPG and YUV being the two most commonly used. RGB24 represents 8 bits each of R, G, and B colors, which can express 256 shades and thus can reproduce 256 x 256 x 256 colors. The YUV format outputs uncompressed video frames, which takes up less system resources and does not require a decoder. The MJPG format outputs video frames obtained by compressing video images in the JPEG format. The relative frame rate is high, the image is mosaic, and it takes up a lot of space. PC system resources are more.

 

(3) Automatic white balance adjustment (Auto)

Automatic white balance adjustment is a function where the camera automatically adjusts the white balance of the image to ensure that white objects appear white on the screen in images captured in different color temperature environments. Color temperature refers to the spectral components and color of light, while a low color temperature means more long-wave light components. When the color temperature changes, the camera needs to adjust the ratio of the three primary colors of red, green, and blue to achieve color balance.

 

(4) Image compression method

JPEG is a static image compression method and a lossy compression method. The greater the compression ratio, the worse the image quality. When image accuracy is not required and storage space is limited, you can choose to use the JPEG format. Most digital cameras use the JPEG format for image compression.

 

(5)Resolution and field of view

Resolution and field of view are two important indicators of endoscopic cameras. Resolution is the camera's ability to distinguish images, and its maximum value is determined by the pixel value of the camera. Field of view refers to the horizontal or vertical angle range that the lens can cover. Generally speaking, the larger the field of view, the wider the scene range captured by the camera, and the observation angle becomes larger. On the contrary, when the field of view is small, the displayed range will be very narrow, and only a very small range can be clearly displayed.

 

(6)Frame rate

In addition to resolution and field of view, frame rate is also an important factor in camera picture quality. Frame rate can be understood as the number of images sampled by the camera per second. The higher the frame rate, the smoother the picture. Generally speaking, only when the number of frames refreshed is more than 24 frames per second, the human eye will not notice obvious pauses.

Currently, due to cost constraints, the maximum frame rate of mainstream cameras is usually 30 frames/second, while low-end products usually only have 15 frames/second or lower. Better-performing cameras should have the ability to achieve a maximum frame rate of 30 frames/second (352×288). Even when shooting in the standard VGA format (640×480), it should have a refresh rate of 15 frames/second.

 

(7) Depth of field

Depth of field refers to the range within which the object captured by the lens appears clear on the plane where the lens is located. The size of the depth of field is related to the focal length, aperture and object distance of the lens. When the focal length, aperture is larger or the object is farther away, the depth of field will be larger and a wider range of objects can be displayed. Otherwise, the depth of field will be smaller. Only a very small range can be clearly displayed, which is why the focus and aperture need to be adjusted frequently during endoscopy. The longer the focal length, the smaller the depth of field; the shorter the focal length, the smaller the depth of field.

 

6, Precautions for daily use of endoscopes

(1) Protect the endoscope camera sensor device: Avoid looking the endoscope lens directly into the sun, choose an appropriate location or install a sun visor to reduce the impact on the lens.

(2) Avoid contact with harmful substances: Avoid contact with oil, steam, water vapor, moisture, dust and other substances. If contacted, clean it immediately. Although many endoscopes now have an IP67 waterproof rating, they should not be immersed in water or oil for a long time. If they come into contact with water or oil, they should be cleaned immediately to ensure long-term use of the product.

(3)Clean the lens correctly: Use a soft cloth with a little alcohol to gently wipe the surface of the lens. Avoid using irritating detergents or organic solvents.

(4) Connect the endoscope correctly: Pay attention to the corresponding power supply voltage value, avoid pulling or twisting the connecting wire, and ensure good contact between the camera and the connecting wire.

(5) Do not disassemble the endoscope at will: The endoscope is glued before leaving the factory. Do not disassemble it at an angle and try to touch its internal parts, which may cause damage to the controller and PCB board.

​

 